head
nav
   
                                                                                                                                                                                        
CP-06 AC/DC Current Probe

 

  • AC/DC Current Measurement
  • Amorphous Alloy Core
  • test range:  400mA,26us,4A,3us,40A,3us
  • 1KHz(in sine wave -1db),10kHz(in sine wave -3dB)
  • Noise:10mA
  • Low battery indication
  • Small size,Light weight
  • Jaw size:6.5mm(Max)
  • Specification
    Specifications Range Accuracy ± (%rdg + digits)
    DCA 400mA ±2.0%rdg±1mA
    4A ±1.0%rdg±5mA
    40A ±1.0%rdg±30mA
    ACA 400mA ±2.0%rdg±1mA
    4A ±1.5%rdg±3mA
    40A ±1.5%rdg±30mA
    Output Sensitivity 1mA/1mV(400mA)
    10mA/1mV(4A)
    0.1A/1mV(40A)
    Power Supply 1.5Χ2battery(AA)
    Size 180(L)±44(W)±30(H)mm
    Weight Approx.200g
    Operating Temperature 0℃ to 50℃ below 80% RH
    Storage Temperature -20℃ to 60℃ below 70% RH
    Accessories Test lead ,Battery,Manual