head
nav
   
                                                                                                                                                                                        
KT-3084 Leakage Clamp Meter

           Click for large photo

  • Digital clamp meter designed for leakage current measurement
  • Least affected by external stray magnetic field
  • The minimum resolution is 0.1mA
  • Data hold function,peak hold function
  • Duty cyde 0.1%~99.9%
  • Diode Test & Audible Continuity
  • Auto Power Off, Auto Range,Capacitance test
  • 40mm large jaw diameter,large 3 3/4 digits LCD (3999 counts)
  • Protest against water and dust
  • Designed to meet international safety standard IEC 61010-1 CAT.III 300V

Specification
Specifications Range

Accuracy± (%rdg+dgts)

DC Voltage 400mV
1.0%rdg+2
4/40/400V
0.8%rdg+2
1000V
1.0%rdg+2
AC Voltage 400mV
1.8%rdg+5
4/40/400V
1.0%rdg+3
750V
1.5%rdg+3
DC/AC Current 400/600A
2.0%rdg+ 5
Capacitance 40nF
2.5%rdg+10
400n/4μF
2.0%rdg+3
40μF
2.5%rdg+3
100μF
5.0%rdg+25
Resistance(Ω) 400Ω
1.5%rdg+2
4K/40K/400K/4MΩ
1.0%rdg+2
40MΩ
2.0%rdg+2
Frequency 10/100/1K/10K/100K/1M/10MHz
0.2%rdg+3
Diode Test Obverse voltage descent: 1F≈1mA
Reverse voltage approx. 1.5V

3.0%rdg+3
Audible Continuity Continuity beeper below 100(Ω),Beeper will sound
Dimensions 228mm(L) x 76mm(W) x 39mm(H)